F WARNING: always clean the Flash Window before use with the lint-free cloth provided to ensure there
is no oil or debris on the lens.
, Skin Contact Sensor (g. 1- 13&20)
The Skin Contact Sensor is a safety mechanism that prevents the device from accidental activation. In order
for the device to activate, the Skin Contact Sensor must be fully depressed against the skin.
, Flash Button (g. 1-5)
TheFlashButtonislocatedonthehandpiece.Toactivatetheashbulb,ensuretheSkinContactSensoris
fully engaged and press the Flash Button.
, Bulb Status Indicator Display (g. 1-8)
The device is ready to ash when the Bulb Status Indicator Display is illuminated green.
NOTE: if the Flash Button is pressed AND the Skin Contact Sensor is not fully engaged OR the Bulb Status
Indicator Display is not illuminated, an audible “beep” will sound. When the Bulb Status Indicator Display
illuminatesyellow,thereare150ashesremainingintheashbulb.WhentheBulbStatusIndicatorDisplay
ashesyellow,thebulbcartridgehasbeenusedupandwillnolongeroperate.Youmustreplacethebulb
cartridge to continue using the device.
, Treatment Head Release Buttons (g. 1-14)
Press both buttons and gently pull to remove the treatment head.
F WARNING: ALWAYSensuretheunitisOFFandthepowercordisdisconnectedbeforeremovingthenose
cone.IfthenoseconeisremovedwhiletheunitispoweredON,allindicatorlightsonthebaseunitwillash
and audible “beeps” will sound.
C
GETTING ACQUAINTED WITH i-LIGHT
, Long-Life Light Cartridge (g. 1-15)
Thelong-lifelightcartridgewilldeliver65,000ashesregardlessoftheenergylevelselected.Whileitis
unlikely you will ever need to replace it; it can be replaced by another long-life cartridge or SP-6000SB which
delivers1,500ashespercartridge.PleasecontactyourlocalRemington®ServiceCentre.
, Energy Level Selection (g. 1-6)
The i-Light device is equipped with 5 energy levels. Level 1 is the lowest setting and level 5 is the highest
setting.
TIP:Forthemosteectiveresults,alwaysusethehighestenergylevelthatdoesnotcausediscomfortonthe
skin. To determine the energy level being used, observe the number of lights illuminated on the Energy
Level Display (g 1 - 9).
Youri-LightdevicewillautomaticallybesettoEnergyLevel1eachtimethedeviceispoweredON.To
change the level, press the Energy Level Selection Button.
, Test the i-Light device on your skin
1. Review the Warnings and Safety Precautions.
2. Familiarise yourself with the features of the i-Light.
3. Consult the Skin Tone Chart to ensure your skin colour is in the acceptable range (g. 5).